LI-COR,
Inc. Phone: (402)
467-0700 |
MATERIAL SAFETY DATA SHEET
|
926-08588 |
24 Hour Phone (CHEMTREC) (800)424-9300
|
1. PRODUCT IDENTIFICATION
IRDye HIV-1 Protease Assay Kit,--926-08588
2. COMPOSITIONS AND INFORMATION ON INGREDIENTS
-------------------------------------------------------------------------------------------------------
Chemical Name CAS# W/V% EXPOSURE LIMITS IN AIR-OSHA
NE = NOT ESTABLISHED PEL STEL IDLH OTHER
mg/m3 mg/m3 mg/m3 mg/m3
Kit Components IRDye HIV-1 Protease Assay Kit
Component A: IRDye labeled HIV-1 protease peptide substrate, lyophilized
None of the components in this mixture have an established exposure limit, or contribute
significantly to the hazards associated with the product. All hazard information pertinent to this
product has been provided in this Material Safety Data Sheet per requirements of the OSHA
Hazard Communication Standard (29 CFR 1910.1200)
Component B: IRDye800CW fluorescence standard, lyophilized
None of the components in this mixture have an established exposure limit, or contribute
significantly to the hazards associated with the product. All hazard information pertinent to this
product has been provided in this Material Safety Data Sheet per requirements of the OSHA
Hazard Communication Standard (29 CFR 1910.1200)
Component C: Pepstatin A
Methyl Sulfoxide 67-68-5 >.99 NE NE NE NE
Component D: HIV Protease Assay Buffer
Sodium acetate 127-09-3 <.01 NE NE NE NE
Sodium chloride 7647-14-5 <.01 NE NE NE NE
EDTA 600-00-4 <.01 NE NE NE NE
Bovine serum
albumin (BSA) 9048-46-8 <.01 NE NE NE NE
Water 7732-18-5 Balance NE NE NE NE
Component E: HIV Protease Stop Solution
Potassium phosphate
monobasic 7778-77-0 <.01 NE NE NE NE
Potassium Phosphate
Dibasic 7758-11-4 <.01 NE NE NE N
Water 7732-18-5 Balance NE NE NE NE
-------------------------------------------------------------------------------------------------------
3. HAZARD IDENTIFICATION
Component C: Methyl Sulfoxide


Hazard Symbols:
Irritant
Risk Phrases:
R36/37/38 Irritating to eyes, respiratory system and skin.
Safety Phrases:
S26, 36/37/39, 45 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Wear suitable protective clothing, gloves and eye/face protection. In case of of accident or if you feel unwell seek medical advice immediately (show label where possible).
Classification system: The classification was made according to the latest editions of the EU lists, and expanded upon from company literature data.
Emergency Overview: All hazard information pertinent to this product has been provided in the Material Safety Data Sheet per requirements of the OSHA Hazard Communication Standard (29 CFR 1910.1200). |
4. FIRST AID MEASURES
Skin Exposure: Caused
irritation to skin. Symptoms include redness, itching and pain.
May cause scaling. Readily absorbed through the skin. Garlic-like
taste and odor may develop on the breath and skin. Transient disturbances
of color vision, headache, diarrhea and dermatitis may result from skin applications.
A solvent; may result in the increase skin absorption of other more toxic
materials. Remove any contaminated clothing, taking care not to contaminate
eyes.
Eye Exposure: Causes irritation, redness and pain. May
cause blurred vision. If liquids or vapors of this product's components
enter the eyes, open victim's eyes while under gently running water. Use
sufficient force to open eyelids. Have victim "roll" eyes.
Minimum flushing is for 15 minutes.
Inhalation: Causes irritation to the respiratory tract.
Symptoms may include coughing, shortness of breath. May cause allergic
reaction in sensitive individuals. If vapors, mists or sprays of the products
components are inhaled, causing irritation, remove victims to fresh air.
If necessary, use artificial respiration to support vital functions. Remove
or cover gross contamination to avoid exposure to rescuers.
Ingestion: Causes irritation to the gastrointestinal tract.
Symptoms may include nausea, vomiting and diarrhea. May cause abdominal
pain, drowsiness, chills and chest pain. If this product is swallowed, CALL
PHYSICIAN OR POISON CONTROL CENTER FOR MOST CURRENT INFORMATION. If professional
advice is not available, do not induce vomiting. Victim should drink milk,
egg whites, or large quantities of water. Never induce vomiting or give
diluents (milk or water) to someone who is unconscious, having convulsion,
or unable to swallow.
Victims of chemical exposure must be taken for medical attention. Rescuers should be taken for medical attention, if necessary. Take copy of label and MSDS to physician or health professional with victim.
5. FIRE-FIGHTING MEASURES
Unusual Fire And Explosion Hazards: When
involved in a fire, this material may decompose and produce irritating fumes
and toxic gases.
Flash Point: N/A
Auto ignition Temperature: N/A
Flammable Limits (In Air By Volume, %): LEL:, UEL: N/A
Fire Extinguishing Materials: Use dry chemical, foam or carbon
dioxide.
6. ACCIDENTAL RELEASE MEASURES
Spill And Leak Response: Ventilate area of leak or spill. Remove all sources ignition. Wear appropriate personal protective equipment as specified in Section 8. Isolate hazard area. Keep unnecessary and unprotected personnel from entering. Contain and recover liquid when possible. Use non-sparking tools and equipment. Collect liquid in an appropriate container or absorb with an inert material. (e.g. vermiculite, dry sand, earth) and place in a chemical container. Do not flush to sewer!
In the event of a non-incidental, minimum release, Personal Protective Equipment should be:
Level D: lab gloves, chemical resistant apron, boots and splashes goggles. Absorb spilled liquid with poly pads or other suitable absorbent materials. Decontaminate the area thoroughly. Place all spill residues in a suitable container and seal. Dispose of in accordance with Federal, State and local hazardous waste disposal regulation.
7. HANDLING and STORAGE
Work Practices And Hygiene Practices: As
with all chemicals, avoid getting this product ON YOU or IN YOU. Wash
hands after handling this product. Avoid splashing or spraying this product.
Do not eat or drink while handling this product.
Storage And Handling Practices: All employees who handle this
material should be trained to handle it safely. Avoid breathing vapors
or mists generated by this product. Ensure that containers of this product are
properly labeled. Open containers slowly on a stable surface. Store
vials as directed in the product insert. Keep vials tightly closed when
not in use. Store away from incompatible materials. Inspect vials
containing this product for leaks or damage. Prior to use, read instruction
provided with product.
Protective Practices During Maintenance Of Contaminated Equipment:
Follow practices indicated in Section 6. (Accidental Release Measures).
Make certain that application equipment is locked and tagged-out safely, as
applicable. Always use this product in areas where adequate ventilation
is provided. Decontaminate equipment using soapy water before maintenance
begins. Collect all rinsates and dispose of according to applicable Federal,
State or Local procedures.
8. EXPOSURE CONTROLS-PERSONAL PROTECTION
Ventilation And Engineering Controls: Use
with adequate ventilation. Use a mechanical fan or vent area to outside,
if necessary. Eye-wash stations should be available near location where
his product is used.
Respiratory Protection: Respiratory protection is generally
not needed when using this product. Maintain airborne contaminant concentration
below limits listed in Section 2. (Composition and Information on Ingredients).
If respiratory protection is needed, use only protection authorized in 29 CFR
1910.134 or applicable State regulations. Use supplied air respiration protection
if oxygen levels are below 19.5% or are unknown.
Eye Protection: Splash goggles, safety glasses or full face
shield where splashing is possible.
Skin Protection: Wear impervious protective clothing, including
gloves, lab coat, apron as appropriate to prevent skin contact.
9. PHYSICAL and CHEMICAL PROPERTIES
| Relative Vapor Density
(Air =1): N/A Specific Gravity (Water=1): N/A Solubility In Water: Miscible in water Appearance And Color: Clear, hygroscopic How To Detect This Substance: N/A |
Evaporation Rate:
Similar to water Freezing/melting Point: N/A Boiling Point: N/A Ph: N/A |
10. STABILITY and REACTIVITY
Stability: Stable
Decomposition Products: Will not occur.
Hazardous Polymerization: Will not occur.
Conditions To Avoid: Heat, flames, ignition sources and incompatible
chemicals.
11. TOXICOLOGICAL INFORMATION
Toxicity Data:The specific toxicology
data available for components greater than 1% in concentration are as follows:
Suspected Cancer Agent: The chemicals in the product's solutions
are not found on the following lists: NTP, IARC, Federal OSHA Z-list and CAL-OSHA,
and therefore are not considered to be, nor suspected by these agencies, to
be cancer causing agents.
Irritancy Of Product: Prolonged skin over-exposure to this
component may cause dermatitis (red, dry skin). Eye over-exposure may
cause temporary cornea damage.
Sensitization To The Product: The chemicals in this product's
solutions are not know to be sensitizer with prolonged or repeated use.
Reproductive Toxicity Information: Listed below is information
concerning the effects of this product and its components on the human reproductive
system.
Mutagenicity: This product is not reported to produce mutagenic
effects in humans.
Embryo toxicity: This product is not reported to cause human
teratogenic effects. Refer to the following paragraph for additional information.
Teratogenicity: This product is not reported to cause human
teratogenic effects.
Reproductive Toxicity: This product is not reported at this
time to cause adverse reproductive effects in humans.
Medical Condition Aggravated By Exposure: Skin disorders
may be aggravated by over-exposure to Dimethyl Sulfoxide. No specific
medical conditions are known to be aggravated by exposure to other solutions
of this product.
Biological Exposure Indices (BEI's): Currently, there are no
Biological Exposure Indices (BEI's) applicable to the components of this product.
12. ECOLOGICAL INFORMATION
Environmental Stability: When released into
the soil, this material is not expected to biodegrade. When released into
the soil, this material may leach into the groundwater this material may evaporate
to a moderate extent. When released into water, this material may evaporate
to a moderate extent. This material is not expected significantly to bio
accumulate. When released in to the air, this material may be moderately
degraded by reaction with photochemical produced hydroxyl radicals. When
released into the air, this material may be removed from the atmosphere to a
moderate extent by wet deposition.
Effect Of Material On Plants Or Animals: No information found.
13. DISPOSAL CONSIDERATIONS
Preparing Wastes For Disposal: Waste Disposal
must be in accordance with appropriate Federal, State and local regulation.
This product, if altered by use, may be disposed of by treatment at a permitted
facility or as advised by your local hazardous waste regulatory authority.
EPA Waste Number: Not applicable to this product.
14. TRANSPORTATION INFORMATION
This material is not hazardous as defined by 49 CFR 172.101 by the U.S. Department of Transportation. This material is not considered as Dangerous Goods.
Proper Shipping
Name: N/A
Hazard Class Number And Description: N/A
UN Identification Number: N/A
Packing Group: N/A
15. REGULATORY INFORMATION
SARA Reporting Requirements: These chemicals are not subject to Sections 302, 304, and 313 reporting requirements under the Superfund Amendment and Reauthorization Act.
Chemical SARA 302 SARA 304 SARA 313
SARA Threshold Planning Quantity: N/A
TSCA Inventory Status: The components of this product are listed
on the TSCA inventory.
CERCLA Reportable Quantity
(RQ): N/A
Other Federal Regulations: N/A
16. OTHER INFORMATION
|
Created: 09/21/07 |
Prepared By LI-COR, Inc.
|