MATERIAL SAFETY DATA SHEET
|
Part No. 928-40032 |
24 Hour Phone (CHEMTREC) (800)424-9300
|
1. PRODUCT IDENTIFICATION
5X New Blot™ PVDF Stripping Buffer
2. COMPOSITIONS AND INFORMATION ON INGREDIENTS
-------------------------------------------------------------------------------------------------------
Chemical Name CAS# W/V% EXPOSURE LIMITS IN AIR-OSHA
NE = NOT ESTABLISHED PEL STEL IDLH OTHER
mg/m3 mg/m3 mg/m3 mg/m3
COMPONENTS: Buffer Solution
Water 7732-18-5 <95 NE NE NE NE
Proprietary <02 2mg/m3 NE NE 10mg/m3 ACGIH
-------------------------------------------------------------------------------------------------------
3. HAZARD IDENTIFICATION

Stripping Buffer
Hazard Symbols:
C
Risk Phrases:
R 35 Causes severe burns
Safety Phrases:
S 26/27 In case of contact with eyes, rinse immediately with plenty of
water and seek medical advice. Take off immediately all contaminated clothing
S 37/39 Wear suitable gloves and eye/face protection.
S 45 In case of accident or if you feel unwell, seek medical advice
immediately (show the label where possible).
Classification system: The classification was made according to the latest editions of the EU lists, and expanded upon from company literature data.
WARNING:
Eye contact may result in permanent eye damage. Irritant. Causes eye and skin irritation. May cause respiratory tract irritation. Corrosive to aluminum. Target Organs: Eyes, skin. |
Symptoms of
Over-Exposure by Route of Exposure:
Eye: Causes eye irritation. May cause chemical conjunctivitis and corneal damage.
Skin: Causes skin irritation.
Ingestion: May cause gastrointestinal irritation with nausea, vomiting and diarrhea.
Inhalation: May cause respiratory tract irritation.
Chronic: No information found.
4. FIRST AID MEASURES
Eyes: Get medical aid. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical aid.
Skin: In case of contact, flush skin with plenty of water. Remove contaminated clothing and shoes. Get medical aid if irritation develops and persists. Wash clothing before reuse.
Ingestion: If swallowed, do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical aid.
Inhalation: Remove from exposure and move to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid.
Notes to Physician: Treat symptomatically and supportively.
5. FIRE-FIGHTING MEASURES
Unusual Fire And Explosion Hazards: When
involved in a fire, this material may decompose and produce irritating fumes
and toxic gases (including carbon monoxide, carbon dioxide and oxides of nitrogen).
Flash Point, °C: N/A
Auto ignition Temperature, °C: N/A
Flammable Limits (In Air By Volume, %): N/A
Fire Extinguishing Materials: NA
NFPA Rating: (estimated) Health: 2; Flammability: 0; Instability: 0
6. ACCIDENTAL RELEASE MEASURES
Spill And Leak Response: For small releases take basic hygiene precautions. Gloves, a lab coat, and eye protection should be worn. Absorb spilled material with vermiculite. Wash contaminated area with soap and water, absorb with vermiculite and rinse with water. Trained personnel using pre-planned procedures would respond to large releases that are not immediately controlled. Proper protection equipment should be used. In case of a spill, clear the affected area, protect people and respond with trained personnel.
In the event of a non-incidental, minimum release, Personal Protective Equipment should be:
Level D: lab gloves, chemical resistant apron, boots and splashes goggles. Respiratory protection should not be necessary. Absorb spilled liquid with poly pads or other suitable absorbent materials. Decontaminate the area thoroughly. Place all spill residues in a suitable container and seal. Dispose of in accordance with Federal, State and local hazardous waste disposal regulation.
7. HANDLING and STORAGE
Work Practices And Hygiene Practices: As
with all chemicals, avoid getting this product ON YOU or IN YOU. Wash
hands after handling this product. Avoid splashing or spraying this product.
Do not ear or drink while handling this product.
Storage And Handling Practices: All employees who handle this
material should be trained to handle it safely. Avoid breathing vapors
or mists generated by this product. Ensure that containers of this product are
properly labeled. Open containers slowly on a stable surface. Store
vials as directed in the product insert. Keep vials tightly closed when
not in use. Store away from incompatible materials. Inspect vials
containing this product for leaks or damage. Prior to use, read instruction
provided with product.
Protective Practices During Maintenance Of Contaminated Equipment: Follow practices indicated in Section 6 (Accidental Release Measures).
Make certain that application equipment is locked and tagged-out safely, as
applicable. Always use this product in areas where adequate ventilation
is provided. Decontaminate equipment using soapy water before maintenance
begins. Collect all rinsates and dispose of according to applicable Federal,
State or Local procedures.
8. EXPOSURE CONTROLS-PERSONAL PROTECTION
Ventilation And Engineering Controls: Use
with adequate ventilation. Use a mechanical fan or vent area to outside,
if necessary. Eye-wash stations should be available near location where
his product is used.
Respiratory Protection: Respiratory protection is generally
not needed when using this product. Maintain airborne contaminant concentration
below limits listed in Section 2. (Composition and Information on Ingredients).
If respiratory protection is needed, use only protection authorized in 29 CFR
1910.134 or applicable State regulations. Use supplied air respiration protection
if oxygen levels are below 19.5% or are unknown.
Eye Protection: Splash goggles or safety glasses.
Hand Protection: Wear butyl rubber gloves for routine industrial
use.
Body Protection: Use body protection appropriate for task,
such as a lab coat.
9. PHYSICAL and CHEMICAL PROPERTIES
| Relative Vapor Density
(Air =1): N/A Specific Gravity (Water=1): N/A Solubility In Water: Soluble Appearance And Color: Clear liquid How To Detect This Substance: There are no unusual warning properties associate with these solutions. |
Evaporation Rate: N/A Freezing/melting Point: N/A Boiling Point: N/A Ph: 13 (-20 C) |
10. STABILITY and REACTIVITY
Stability: Stable under normal room temperature and closed container.
Decomposition Products:Toxic fumes of sodium oxide
Hazardous Polymerization: Will not occur
Conditions To Avoid: Metals and Acids .
11. TOXICOLOGICAL INFORMATION
Toxicity Data:
RTECS#:
CAS# 7732-18-5: ZC0110000
CAS# 1310-73-2: WB4900000
LD50/LC50:
CAS# 7732-18-5:
Oral, rat: LD50 = >90 mL/kg;
CAS# 1310-73-2:
Draize test, rabbit, eye: 400 ug Mild;
Draize test, rabbit, eye: 1% Severe;
Draize test, rabbit, eye: 50 ug/24H Severe;
Draize test, rabbit, eye: 1 mg/24H Severe;
Draize test, rabbit, skin: 500 mg/24H Severe;
Carcinogenicity:
CAS# 7732-18-5: Not listed by ACGIH, IARC, NTP, or CA Prop 65.
CAS# 1310-73-2: Not listed by ACGIH, IARC, NTP, or CA Prop 65.
Epidemiology: No information found
Teratogenicity: No information found
Reproductive Effects: No information found
Mutagenicity: No information found
Neurotoxicity: No information found
12. ECOLOGICAL INFORMATION
Environmental Stability: The chemicals in
this product's solutions will degrade in the environment into organic and inorganic
constituents.
Effect Of Material On Plants Or Animals: No unusual effects
on plants or animals are expected if this product is released into the environment.
See Section 11 (Toxicological Information) for further information regarding
the effects of chemicals in this product's solutions on test animals.
13. DISPOSAL CONSIDERATIONS
Preparing Wastes For Disposal: Waste Disposal
must be in accordance with appropriate Federal, State and local regulation.
This product, if altered by use, may be disposed of by treatment at a permitted
facility or as advised by your local hazardous waste regulatory authority.
EPA Waste Number: Not applicable to this product.
14. TRANSPORTATION INFORMATION
This material is hazardous as defined by 49 CFR 172.101 by the U.S. Department of Transportation. This material is considered as Dangerous Goods.
Contact LI-COR Biosciences for Transportation Information.
15. REGULATORY INFORMATION
SARA Reporting Requirements: These chemicals are not subject to Sections 302, 304, and 313 reporting requirements under the Superfund Amendment and Reauthorization Act.
Chemical
SARA 302
SARA 304
SARA 313
SARA Threshold Planning Quantity:
N/A
TSCA Inventory Status: N/A
CERCLA Reportable Quantity
(RQ): 1000 lbs. (454 Kg) RQ
Other Federal Regulations: N/A
16. OTHER INFORMATION
|
Created: 03/13/08 |
Prepared By LI-COR, Inc.
|